Common Overcurrent Phenomena in Frequency Inverters

Overcurrent faults in frequency inverters, also known as variable frequency drives (VFDs), account for approximately 40-45% of all inverter failures, making them a prevalent issue. Modern frequency inverters are equipped with several overcurrent protection functions, including short circuit protection, acceleration/deceleration overcurrent protection, and constant speed overcurrent protection.

Common-overcurrent-phenomena-in-Frequency-Inverters

External Causes of Frequency Inverter Current Phenomena

External factors often contribute to overcurrent faults. These include burned windings in the motor being driven by the inverter, short circuits in the load-side cabling, or mechanical issues that lead to increased load. Identifying these problems typically involves isolating the inverter from its load and conducting tests to pinpoint the fault.

The Inherent Reasons of the Frequency Inverter Current Phenomenon

Inherent causes within the frequency inverter itself can also lead to overcurrent events. Issues may arise from anomalies in the current sampling components, rectification circuits, or faults in the IGBT/IPM power module. If these components fail, they can trigger overcurrent conditions. A straightforward method to diagnose these faults is to test the inverter independently from the motor.

Three Aspects of Common Frequency Inverter Overcurrent Phenomena

Immediate Overcurrent Fault on Power-Up: This often cannot be reset and is typically due to damaged IGBT/IPM modules, abnormal drive signals, or failures in the current detection circuitry. Timely repair is essential to prevent further damage.

Normal Standby but Overcurrent During Operation: If the inverter shows normal status while idle but triggers overcurrent when running, this may be due to issues with the connected motor or mechanical blockages. In this case, users should avoid running the inverter until the problem is resolved.

Overcurrent During Acceleration: If the inverter operates normally at startup but triggers overcurrent during acceleration, it often indicates misconfigured parameters, such as a short acceleration time or an incorrectly set motor current rating. Adjusting these settings can help alleviate the issue.

By understanding these common phenomena, users can better manage frequency inverter operations and maintain optimal performance.

上一篇文章
What Are the Functions of the Dedicated Line Reactor for Frequency Inverter?
下一篇文章
Canton Fair – Global Share

有什么你找不到的吗?

与我们的销售团队联系

USFULL专注于全球市场,并为客户提供适合当地市场的优质产品:

  • 综合手册可下载
  • 1-3年质量保证
  • 闪电般的交付
  • 支持OEM & ODM
  • 24小时快速响应
  • 高效的生产能力
  • 更低的产品起订量

欢迎给我发送邮件

fullwill@www.usfull.cn

联系我们

我们坚定不移地致力于客户并提供尖端创新,USFULL在未来的旅程中成为您坚实的盟友。

请在浏览器中启用JavaScript来完成此表单。
请输入您的名字
请输入邮箱或者微信账号
输入您的联系方式
您所在的地区
尽可能具体的告诉我们您的需求

相关产品

未找到结果。